Aortic Repair Durability Tied to Hostile Neck Burden and Morphology
In an extensive evaluation of endovascular aneurysm repair for abdominal aortic aneurysms, clinical researchers at Nanjing Drum Tower Hospital demonstrated that standard stent-grafting achieved equivalent early safety between patients with hostile proximal nec
Illustrative imageIn an extensive evaluation of endovascular aneurysm repair for abdominal aortic aneurysms, clinical researchers at Nanjing Drum Tower Hospital demonstrated that standard stent-grafting achieved equivalent early safety between patients with hostile proximal neck anatomy and those presenting with standard vascular geometry, while mid-term durability diverged primarily among individuals exhibiting multiple adverse anatomical features or specific tapered contours. The retrospective investigation, examining clinical and radiological records across a defined cohort of infrarenal aneurysm cases treated with elective procedures between January 2019 and December 2021, tracked patient outcomes across a rigorous two-year postoperative surveillance window. Although the overarching comparison between the hostile proximal neck cohort and the standard anatomy cohort showed a numeric elevation in secondary interventions that ultimately stopped short of conventional statistical significance, deeper analytical stratification revealed that anatomical burden is not a uniform binary state. Patients with multiple compounding irregularities in their proximal landing zone faced significantly elevated risks of surgical or endovascular reintervention over the initial twenty-four months, challenging conventional binary definitions of anatomical hostility.
The study protocol began by screening six hundred thirty-seven consecutive individuals diagnosed with abdominal aortic pathology who underwent endovascular aneurysm repair at the tertiary medical center’s vascular surgery division. To maintain methodological rigor and eliminate procedural confounding, investigators applied strict exclusion criteria that narrowed the final study population to three hundred ninety-eight patients treated exclusively for infrarenal aneurysms using standard elective endovascular repair. The research team systematically excluded seventy-eight individuals presenting with non-infrarenal aneurysms or alternative aortic diseases, fifty-seven patients who required non-standard endovascular configurations, twenty-four individuals lacking adequate or accessible preoperative computed tomography angiography for centerline-based morphological measurements, thirty-five patients undergoing secondary revisions following prior aortic operations, and forty-five patients without recorded post-discharge follow-up data. All forty-five excluded follow-up patients were verified alive upon initial hospital discharge, though their long-term survival and potential reintervention courses could not be independently ascertained from hospital records.
Among the three hundred ninety-eight patients who formed the analyzed cohort, two hundred sixty-six were categorized into the standard anatomy group, whereas one hundred thirty-two met defined radiological criteria for the hostile proximal neck group. Proximal landing zone evaluation relied on standardized centerline lumen reconstructions derived from preoperative computed tomography angiography, with measurements reviewed independently by a senior vascular surgeon involved in clinical planning and a senior radiologist blinded to patient identity and clinical decisions. Hostile anatomy was formally identified by the presence of at least one of four core morphological irregularities: a short proximal aortic neck length under fifteen millimeters, severe infrarenal angulation exceeding sixty degrees between the infrarenal neck and the longitudinal axis of the aneurysm sac, circumferential calcification or mural thrombus covering more than fifty percent of the proximal landing zone circumference, or a tapered or reverse-tapered neck geometry defined as an absolute difference greater than two millimeters between proximal and distal neck diameters within the initial ten millimeters below the lowest renal artery.
Patients assigned to the hostile proximal neck cohort presented with substantially greater demographic and anatomical complexity than their standard anatomy counterparts. Individuals in the hostile group were significantly older on average, with a mean age of 73.63 years compared to 69.09 years in the standard group, and exhibited a higher mean body mass index of 24.86 kilograms per square meter compared to 23.78 kilograms per square meter. Aneurysm architecture was notably more demanding in the hostile cohort, featuring a larger mean maximum sac diameter of 74.73 millimeters versus 59.83 millimeters, a shorter mean proximal neck length of 13.74 millimeters versus 18.93 millimeters, a wider mean neck diameter of 24.52 millimeters versus 23.41 millimeters, and an average infrarenal neck angulation of 60.80 degrees compared to 44.73 degrees. Conversely, baseline prevalence rates of male sex, history of tobacco smoking, hypertension, and diabetes mellitus did not exhibit statistically significant divergence between the two study arms. Within the hostile anatomy cohort, severe neck calcification or mural thrombus represented the most frequent adverse feature, observed in 75.8 percent of patients, followed by severe angulation in 50.8 percent, short neck length in 48.5 percent, and tapered or reverse-tapered contours in 21.2 percent.
Immediate procedural performance and short-term safety profiles showed remarkable parity across both anatomical categories despite the underlying vascular disparities. The surgical teams achieved primary technical success, defined as accurate deployment of the endograft in the intended landing zone without conversion to open surgical repair or intraoperative mortality, in one hundred percent of patients in both groups. General anesthesia served as the predominant anesthetic approach in 94.5 percent of the total patient population, while percutaneous femoral access was utilized in 71.4 percent of standard cases and 80.3 percent of hostile cases. To optimize seal and fixation, planned adjunctive procedural maneuvers—including proximal balloon modeling, aortic cuff placement, staged deployment techniques, or coil embolization—were implemented in twenty-five standard anatomy patients and twenty-one hostile neck patients. Serious adverse events within thirty days post-implantation occurred in 3.0 percent of standard anatomy cases and 2.3 percent of hostile anatomy cases, while overall thirty-day adverse events occurred in 7.5 percent versus 7.6 percent, with both safety endpoints showing identical statistical equality. Crucially, zero reinterventions were required within the initial thirty-day window, and zero all-cause or aneurysm-related deaths occurred either within thirty days or throughout the two-year surveillance timeline across all analyzed patients.
Over the entire two-year follow-up timeframe, unplanned secondary interventions were documented in forty-five patients in the standard anatomy group, representing a crude reintervention rate of 16.9 percent, and in thirty-two patients in the hostile proximal neck group, reflecting a crude rate of 24.2 percent. Kaplan–Meier survival estimates established a two-year freedom from reintervention rate of 83.1 percent for standard anatomy cases compared to 75.8 percent for hostile neck cases, generating a log-rank P value of .078 that did not reach the threshold for formal statistical significance. Primary time-to-event modeling using unadjusted Cox proportional hazards regression produced a hazard ratio of 1.50 with a 95 percent confidence interval spanning 0.95 to 2.36. Sequential adjustment for baseline clinical characteristics—specifically patient age, sex, body mass index, smoking history, hypertension, and diabetes mellitus—yielded an adjusted hazard ratio of 1.60 with a 95 percent confidence interval of 0.99 to 2.60. Sensitivity testing that incorporated sex stratification and modeled time-varying age effects to address non-proportional hazards generated a concordant hazard ratio of 1.60 with a 95 percent confidence interval of 0.98 to 2.61, indicating that while risk estimates remained elevated, their confidence boundaries encompassed unity.
The etiology of mid-term secondary interventions was cataloged across the seventy-seven total qualifying reintervention events identified throughout the follow-up period. Type II endoleaks requiring therapeutic intervention formed the single largest indication for secondary procedures, accounting for thirty-one total cases, or 40.3 percent of all reinterventions, comprising seventeen events in the standard anatomy cohort and fourteen events in the hostile anatomy cohort. Type Ia endoleaks, which directly reflect compromised or failing seal at the proximal landing zone, represented the second most prevalent cause, totaling twenty-three cases, or 29.9 percent of all reinterventions, including thirteen events in the standard anatomy group and ten in the hostile anatomy cohort. Additional indications necessitating clinical reintervention encompassed twelve cases of iliac limb occlusion representing 15.6 percent, eight cases of type Ib distal endoleak representing 10.4 percent, and three cases of vascular graft infection representing 3.9 percent of total secondary procedures across both cohorts.
A critical contribution of the study emerged from analyzing the cumulative burden of hostile anatomical characteristics rather than treating neck hostility as a monolithic binary condition. When stratifying the entire patient cohort by the exact count of coexisting adverse features, two-year reintervention rates escalated progressively: 16.9 percent in patients with zero hostile features, 14.9 percent in those with one feature, 22.9 percent in those with two features, 34.4 percent in those with three features, and 60.0 percent among patients presenting with all four adverse characteristics. In multivariable Cox models applied to the overall cohort, each additional hostile anatomical feature conferred an independent hazard ratio of 1.40 for reintervention after clinical covariate adjustment. When confining the analysis strictly within the hostile proximal neck group, patients harboring multiple hostile features (two or more) experienced a reintervention rate of 29.4 percent, corresponding to a two-year freedom from reintervention of 70.6 percent, whereas patients with only a single hostile feature achieved an 85.1 percent freedom from reintervention rate. This divergence yielded a significant log-rank P value of .041 and an unadjusted hazard ratio of 2.33, indicating that compounding anatomical challenges markedly undermine mid-term endograft stability.
Exploratory analyses of specific anatomical subtypes underscored unique vulnerability associated with tapered neck configurations. Among twenty-eight patients exhibiting pooled tapered or reverse-tapered morphology, fourteen individuals—or 50.0 percent—underwent reintervention within two years, compared to eighteen reinterventions among one hundred four patients lacking this feature, translating to a rate of 17.3 percent. This contrast generated a hazard ratio of 3.70 in unadjusted Cox regression and 3.61 following adjustment for proximal neck length. Retrospective image reassessment divided these twenty-eight cases into twelve patients presenting with distal tapering or narrowing and sixteen patients with reverse tapering or distal widening. Ten of the twelve patients with tapered necks underwent secondary procedures, representing an 83.3 percent reintervention rate, compared to four of sixteen patients with reverse-tapered necks, representing a 25.0 percent rate, yielding an unadjusted Fisher exact P value of .0063. Furthermore, exploratory subgroup interactions indicated that among patients receiving planned adjunctive maneuvers, hostile anatomy was associated with an elevated hazard of reintervention (hazard ratio 4.41) compared to standard anatomy, whereas no such divergence emerged among patients treated without adjuncts (hazard ratio 1.19), producing an interaction P value of .049 that researchers categorized as hypothesis-generating.
In evaluating four distinct commercial endograft systems deployed during the investigation—comprising one hundred ninety-eight Ankura devices, one hundred fifteen Endurant I systems, forty-seven Aegis devices, and thirty-eight Zenith Flex configurations—crude reintervention proportions hovered within a narrow band between 18.4 percent and 21.3 percent. When researchers fitted an exploratory Cox model incorporating stent-graft platforms alongside clinical and anatomical covariates, the resulting hostile group hazard ratio remained statistically imprecise at 1.08 with a wide confidence interval of 0.41 to 2.85. The authors noted that differing fixation mechanisms, such as the suprarenal anchors of Zenith Flex and Endurant I versus the anatomical fixation design of the unibody Aegis platform, could not be evaluated independently of non-randomized operator device selection. Additional post hoc sensitivity models tested broader neck definitions by incorporating proximal neck diameter thresholds of thirty millimeters or twenty-eight millimeters into the grouping criteria; both alternative thresholds led to progressive attenuation of the adjusted hazard ratio toward the null, demonstrating that observed risk associations are sensitive to specific anatomical classification boundaries.
The authors identified several key methodological limitations that contextualize their conclusions. Beyond its retrospective, single-center framework, the investigation excluded forty-five patients without recorded follow-up data after discharge, which may introduce selection bias. Incomplete post-discharge imaging—with twenty-four-month radiological evaluations available in only 34.4 percent of patients—may have obscured asymptomatic graft anomalies or occult endoleaks. Additionally, institutional sizing protocols mandated proximal oversizing below thirty percent, yet exact individual oversizing percentages were unavailable for retrospective modeling, precluding direct correlation between graft sizing accuracy and type Ia endoleaks. Ultimately, the investigators emphasized that while standard endovascular repair achieves excellent thirty-day safety in carefully selected hostile anatomy, the accumulation of multiple adverse anatomical features and specific neck geometries substantially increases secondary procedural burdens, reinforcing the clinical imperative for meticulous patient selection and dedicated post-implantation surveillance.
Subject of Research: Endovascular aneurysm repair outcomes in patients with hostile proximal aortic neck anatomy
Article Title: Efficacy and safety of endovascular aneurysm repair for abdominal aortic aneurysms with hostile proximal neck anatomy: a single-center retrospective cohort study
Article References: Li, Z., Cai, J., Cheng, X., Li, Q., Liang, Z., Liu, C., & Qiao, T. (2026). Efficacy and safety of endovascular aneurysm repair for abdominal aortic aneurysms with hostile proximal neck anatomy: a single-center retrospective cohort study. Frontiers in Cardiovascular Medicine, 13, Article 1884080. https://doi.org/10.3389/fcvm.2026.1884080
Image Credits: AI Generated
DOI: 10.3389/fcvm.2026.1884080
Keywords: abdominal aortic aneurysm, endovascular aneurysm repair, hostile proximal neck, reintervention, aortic neck angulation, proximal neck length, tapered aortic neck, reverse-tapered neck, vascular surgery, stent-graft durability, type Ia endoleak, type II endoleak, mural thrombus, aortic calcification, adjunctive maneuvers, freedom from reintervention, computed tomography angiography
News Source: Ophelia Keating. (November 26, 2026). Aortic Repair Durability Tied to Hostile Neck Burden and Morphology. Scienmag.