A newly published clinical case report in Burns Open documents how an ignited category F1 ground spinner firework caused a severe, penetrating neck injury and extensive soft tissue damage in a three-year-old child. Category F1 fireworks are legally classified

Illustrative imageIllustrative image

A newly published clinical case report in Burns Open documents how an ignited category F1 ground spinner firework caused a severe, penetrating neck injury and extensive soft tissue damage in a three-year-old child. Category F1 fireworks are legally classified in Europe as presenting a very low hazard risk and are authorized for public purchase and use by children under adult supervision. Despite this low-risk designation, clinicians report that accidental mechanical entrapment of the pyrotechnic device against clothing prevented normal heat dissipation and concentrated hot combustion gases directly against cervical structures, producing deep thermal trauma and the deposition of burning particulate matter.

Under designed operating conditions, ground spinners rotate freely across open ground by discharging hot exhaust gases through a lateral vent, an active motion that naturally disperses thermal energy across a broader surface area. In this incident, the three-year-old girl, who had no prior relevant medical history, was exposed to a lit ground spinner that landed inside the open collar of her jacket on New Year’s Eve. Reflexively bowing her neck downward, the child trapped the rotating device against her skin, arresting its movement and causing the pyrotechnic unit to fully discharge its combustion products against a localized site on the left side of her neck before caregivers could intervene.

Pediatric patients represent a disproportionate share of firework casualties due to developmental limitations in hazard awareness, lower body surface areas, and proximity of the head and neck to ground-level devices. While Dutch authorities have scheduled bans on consumer fireworks in category F2 and higher beginning in the 2026–2027 period, category F1 products such as sparklers, party poppers, and ground spinners will remain available year-round, underscoring the clinical importance of recognizing how non-explosive consumer pyrotechnics can inflict critical physical trauma.

Immediately following the combustion of the trapped device, the child developed hoarseness, drowsiness, and reduced responsiveness, prompting urgent ambulance transfer to the clinic’s emergency department. Given the presence of acute hoarseness and the anatomical vulnerability of the pediatric airway, the attending anaesthesiology team performed rapid endotracheal intubation to secure respiratory function against potential airway compromise. Intubation proceeded without complications, and subsequent direct visualization showed no intraluminal mucosal burn injury within the respiratory tract.

Initial physical examination identified a penetrating burn defect on the left side of the neck measuring approximately 1 centimeter in diameter and associated with active wound exudate. The burn encompassed an estimated 3 percent total body surface area, comprising 2 percent full-thickness third-degree destruction and 1 percent deep partial-thickness second-degree injury. Marked erythema and edema extended across the left cheek, while the surrounding cervical skin demonstrated widespread thermal injury. Diagnostic endoscopy confirmed that the nasopharyngeal structures and vocal cords remained structurally intact, and the major cervical vessels were preserved despite visible tissue discoloration in the adjacent wound bed.

The patient was transferred directly from the emergency room to the operating theater for immediate operative management. Surgical teams executed comprehensive debridement and necrotomy of nonviable tissue, completing primary reconstruction with a split-thickness skin graft before transferring the child to the intensive care unit for early postoperative stabilization. A postoperative chest radiograph performed to verify the position of the endotracheal tube confirmed proper airway placement and revealed numerous radiopaque foreign bodies, consistent with retained gunpowder particles, distributed along the left side of the trachea.

The initial ward course progressed without systemic infection, and repeated dressing changes conducted under sedation confirmed satisfactory graft adherence. However, because of persistent clinical hoarseness, follow-up laryngoscopic evaluation was carried out, which demonstrated complete left vocal cord paralysis with the vocal fold fixed in an adducted position. Despite the functional nerve impairment, the patient achieved stable healing of the skin graft and was discharged home in good clinical condition ten days after the initial debridement procedure.

Four days following hospital discharge, the patient was urgently readmitted after outpatient evaluators identified progressive wound necrosis beneath the reconstructed site. Emergency computed tomography angiography of the cervical vasculature demonstrated extensive, deep soft tissue necrosis beneath the split-thickness skin graft on the left side of the neck. Tissue destruction involved the sternocleidomastoid muscle, the masseter muscle, the parotid gland, and deeper fascial planes, with foreign pyrotechnic particles tracking into the superior anterior mediastinum and bordering the major cervical vessels without acute arterial wall perforation.

To control the secondary tissue necrosis, surgical teams performed an extensive repeat debridement followed by definitive soft tissue reconstruction using an advanced fasciocutaneous transposition flap harvested from the neck and left shoulder. The operative margin was reinforced using a Prevena negative pressure wound therapy dressing to support tissue perfusion and seal the wound borders. The secondary postoperative hospitalization remained uncomplicated, and the patient was successfully discharged seven days following flap reconstruction.

Long-term therapeutic management incorporated conservative scar management regimens, including custom silicone sheet therapy and specialized compression garments. The patient experienced a spontaneous and complete recovery of vocal cord mobility within six months of the injury. At the comprehensive long-term follow-up assessment conducted 6.5 years post-injury, the child demonstrated full functional range of motion in the neck, with only minor fibrous bands discernible during lateral rotation. Evaluation with the Patient and Observer Scar Assessment Scale 2.0 indicated favorable vascularization, minimal color difference, mild hypopigmentation, slightly thickened tissue, and irregular surface texture, yielding a cosmetic result judged overall as good.

The child’s father and brother both required targeted eye movement desensitization and reprocessing therapy to address emotional distress stemming from the event. The patient herself exhibited specific phobic reactions to open flame, intense heat, neck contact, and dense food textures such as hard candy or large food morsels, although her overall psychological wellbeing was preserved at long-term follow-up.

The authors conclude that existing statutory hazard classifications evaluate intended operating conditions rather than maximum destructive capacity, demonstrating that low-category pyrotechnics demand rigorous supervisory vigilance and early surgical particulate clearance.

A key clinical consideration emphasized by the authors is preventing traumatic tattooing from retained pyrotechnic matter. When burning pyrotechnic particles penetrate past the cutaneous barrier into deep tissues, they risk producing permanent discolouration and tissue irritation if not excised prior to re-epithelialisation. This extensive spread demonstrates why pyrotechnic trauma cannot be treated solely as uncomplicated thermal burns.

The authors observe that such complex, deep tissue injuries significantly elevate the risk of hypertrophic scarring and contractures.

The findings emphasize the critical importance of anticipatory guidance and injury prevention within routine paediatric practice. Current regulatory classifications reflect intended conditions of use rather than peak injury potential when normal device rotation is unintentionally disrupted. Although Dutch legislation plans to prohibit consumer fireworks in category F2 and higher starting in the 2026–2027 period, category F1 devices remain legally accessible year-round. Young children remain exceptionally susceptible to severe burns because of their limited danger recognition, small body surface area, and close physical proximity to ground-level fireworks. Clinicians argue that increasing awareness among healthcare providers, caregivers, and policymakers is vital to prevent life-threatening trauma from devices widely presumed to be harmless.

Subject of Research: Pediatric penetrating burn injury caused by an ignited category F1 ground spinner firework

Article Title: Penetrating burn injury caused by an ignited ground spinner (low-risk (F1) firework) in a three-year-old child: a case report

Article References: Dupont, I. V., Wagner, T., & Vehmeijer-Heeman, M. L. A. W. (2026). Penetrating burn injury caused by an ignited ground spinner (low-risk (F1) firework) in a three-year-old child: a case report. Burns Open, 16, Article 100483. https://doi.org/10.1016/j.burnso.2026.100483

Image Credits: AI Generated

DOI: 10.1016/j.burnso.2026.100483

Keywords: ground spinners, category F1 fireworks, pediatric burn injury, penetrating neck trauma, delayed wound necrosis, split skin grafting, fasciocutaneous transposition flap, pyrotechnic particle penetration, vocal cord paralysis, negative pressure wound therapy, surgical debridement, Burns Open, POSAS scar assessment, Netherlands firework regulations, computed tomography angiography, endotracheal intubation, EMDR therapy