LATEST UPDATESEnglish
EEUPAQ NewsA curated stream of attributed news links
Stay close to the storiesA clear view of source-attributed news headlines.
Science

Spleen Imaging Accurately Predicts Esophageal Varices in Schistosomiasis

Splenic ultrasound parameters and spleen stiffness measured by point shear-wave elastography accurately predict the presence of esophageal varices in patients suffering from schistosomiasis-associated non-cirrhotic portal hypertension, according to a prospecti

Illustrative imageIllustrative image

Splenic ultrasound parameters and spleen stiffness measured by point shear-wave elastography accurately predict the presence of esophageal varices in patients suffering from schistosomiasis-associated non-cirrhotic portal hypertension, according to a prospective clinical investigation conducted in northeastern Brazil. The study, published in the journal Abdominal Radiology, demonstrates that diagnostic evaluations focused directly on the spleen perform significantly better than liver-based assessments in identifying vascular collateral vessels in this distinct parasitic condition. By establishing reliable non-invasive indicators, the research team found that measurements of spleen stiffness, splenic vein diameter, and a combined splenic index model could potentially stratify patient risk while reducing dependence on invasive endoscopic screening procedures in clinical settings where resources remain constrained.

Schistosomiasis caused by Schistosoma mansoni represents a widespread parasitic disease and one of the principal causes of non-cirrhotic portal hypertension in endemic areas, particularly within northeastern Brazil where access to clean drinking water and basic sanitation infrastructure is historically limited. The state of Pernambuco accounts for a substantial proportion of severe disease manifestations and disease-related mortality. In patients who develop the hepatosplenic form of schistosomiasis, portal hypertension develops following the chronic lodging of parasite eggs inside intrahepatic terminal portal venules. This persistent entrapment provokes a continuous granulomatous inflammatory reaction, culminating in periportal fibrosis and severe pre-sinusoidal obstruction to blood flow. Notably, this pathological process occurs without triggering extensive primary hepatocellular destruction or disrupting the liver lobular architecture, distinguishing it fundamentally from classic hepatic cirrhosis.

As portal venous obstruction persists, affected individuals concurrently develop marked splenomegaly through an immune-mediated reticuloendothelial hyperplasia induced by adult worms and circulating antigens. The combination of pre-sinusoidal obstruction and increased splenic venous inflow leads to an elevation of portal pressures, which subsequently stimulates the opening of portosystemic collateral pathways. The development of esophageal varices signifies the establishment of clinically significant portal hypertension, carrying a severe risk of life-threatening upper gastrointestinal hemorrhage. Recurrent variceal bleeding episodes often induce secondary hepatic necrosis, leading to progressive clinical deterioration characterized by jaundice, ascites, and hepatic encephalopathy. While upper gastrointestinal endoscopy serves as the traditional reference standard to detect varices, it remains an invasive, costly, and resource-heavy diagnostic procedure that is difficult to implement widely across rural or under-resourced endemic healthcare centers.

To evaluate alternative non-invasive screening approaches, researchers based at the Gastroenterology Division of the Hospital das Clínicas at Universidade Federal de Pernambuco conducted a prospective, cross-sectional evaluation involving 71 consecutive patients diagnosed with schistosomiasis-associated non-cirrhotic portal hypertension. Eligible participants were recruited from a specialized outpatient clinic based on confirmed histories of water exposure in endemic zones, prior antiparasitic treatment with praziquantel, and definitive ultrasound confirmation of periportal fibrosis. The investigative team excluded patients with prior surgical splenectomy, coexisting hepatic steatosis, viral hepatitis B or C coinfection, drug-induced liver toxicity, chronic alcohol abuse, ultrasound evidence of cirrhosis, or hepatocellular carcinoma. Furthermore, patients with absent or questionable fibrosis corresponding to Niamey patterns A and B were systematically excluded, because hemodynamic complications and collateral vessels do not arise in the absence of established periportal fibrosis.

The study cohort displayed a median age of 57 years, ranging from 23 to 79 years, and comprised an approximately equal distribution of sexes, with 50.7 percent male participants and 49.3 percent female participants. Clinical documentation revealed that 35.2 percent of the evaluated patients presented an established medical history of prior upper gastrointestinal bleeding manifested as hematemesis or melena. Most of the enrolled cohort—specifically 77.5 percent—manifested the advanced hepatosplenic clinical form of schistosomiasis. In addition, 76.1 percent of patients exhibited severe, advanced periportal fibrosis patterns classified as grade E or F according to the standardized Niamey classification criteria, confirming a patient sample with substantial chronic fibro-vascular alterations.

All study participants underwent complete upper abdominal ultrasound and point shear-wave elastography on a dedicated Siemens Acuson S2000 diagnostic imaging platform equipped with a 3.5 to 5 megahertz convex transducer, operated by a single sonographer who was blinded to clinical and endoscopic details. The ultrasound evaluation recorded the portal vein diameter, splenic vein diameter, and longitudinal and transverse splenic dimensions, which were multiplied to calculate the splenic index in square centimeters. Tissue stiffness was evaluated using point shear-wave elastography to capture shear-wave propagation velocities in meters per second within both hepatic and splenic parenchyma. Operators obtained a minimum of ten valid measurements per organ, requiring strict technical quality standards characterized by an interquartile range-to-median ratio of no more than 15 percent for liver readings and no more than 30 percent for splenic readings.

The reference standard examination consisted of an upper gastrointestinal endoscopy performed by an independent endoscopist within an interval of less than three months following imaging examinations, during which no hemodynamic medications or variceal band ligations were initiated. Endoscopic examinations detected esophageal varices in 46 out of the 71 patients, representing a prevalence of 64.8 percent within the study cohort. Among patients with confirmed varices, 71.7 percent presented small-caliber lesions classified as grade F1, while medium F2 and large F3 varices accounted for the remaining cases. The varices were predominantly bluish in color in 87.0 percent of cases, localized to the lower third of the esophagus in 54.3 percent, and exhibited high-risk red color signs in 21.7 percent of individuals, while concomitant portal hypertensive gastropathy was identified in 47.9 percent of the total patient group.

Comparative analyses revealed that all ultrasonographic splenic dimensions were significantly larger in individuals harboring esophageal varices compared to those without collaterals. Splenic vein diameter was significantly widened in the varices cohort, yielding a statistically significant difference (p < 0.001), and the splenic index was similarly elevated (p = 0.002). Elastography showed that median splenic shear-wave velocity was significantly higher in patients with esophageal varices at 3.72 meters per second compared to 3.17 meters per second in patients without varices (p < 0.001). Conversely, portal vein diameter did not differ significantly between patients with and without varices. Similarly, median liver stiffness measurements showed no meaningful distinction between groups, measuring 1.53 meters per second in patients with varices and 1.50 meters per second in those without varices.

Receiver operating characteristic curve analysis confirmed the superior diagnostic utility of splenic parameters over hepatic metrics for predicting the presence of esophageal varices. Spleen stiffness measured by point shear-wave elastography achieved the highest individual area under the receiver operating characteristic curve at 0.800, closely followed by splenic vein diameter with an area of 0.783, and the splenic index with an area of 0.722. In contrast, liver stiffness elastography and portal vein diameter demonstrated poor discriminative capacities, registering areas under the curve of only 0.542 and 0.596, respectively. Applying an optimal splenic stiffness cutoff value greater than 3.48 meters per second (approximately 36 kilopascals) yielded a diagnostic accuracy of 78.9 percent, with 73.9 percent sensitivity and 80.0 percent specificity. Splenic vein diameter exceeding 0.69 centimeters demonstrated 78.9 percent accuracy, 78.3 percent sensitivity, and 80.0 percent specificity, whereas a splenic index above 63.96 square centimeters provided high diagnostic sensitivity of 89.1 percent with 60.0 percent specificity.

To explore whether combining multiple diagnostic parameters could enhance non-invasive predictive accuracy, the researchers constructed a multivariable logistic regression model integrating spleen point shear-wave velocity and splenic index. This combined model yielded an area under the curve of 0.821. However, formal pairwise statistical comparisons using DeLong’s test indicated that this numerical improvement was not statistically significant compared to spleen stiffness elastography alone (p = 0.234), nor was there a statistically significant difference between spleen stiffness and splenic vein diameter (p = 0.803). An exploratory subgroup evaluation focusing on high-risk medium-to-large varices similarly revealed no significant difference between the combined model (AUC 0.793) and splenic elastography alone (AUC 0.720; p = 0.295), demonstrating that single splenic parameters deliver diagnostic utility comparable to multivariable equations.

The biological divergence between hepatic and splenic stiffness reflects the unique vascular pathology of schistosomiasis. Unlike cirrhotic portal hypertension, in which diffuse parenchymal scarring and regenerating nodules uniformly elevate liver stiffness, hepatosplenic schistosomiasis preserves hepatic lobular architecture and hepatocytes. Fibrosis remains restricted to the periportal spaces, causing liver stiffness to remain relatively low and unreactive to portal hemodynamic fluctuations. Conversely, the spleen bears the impact of massive downstream venous backpressure alongside reactive reticuloendothelial proliferation and red pulp congestion, making splenic stiffness and venous dilation precise functional indicators of portal hypertension severity. The researchers emphasized that their findings should be viewed as a screening tool to identify the presence of varices rather than a definitive method to grade high-risk lesions, noting limitations that include a single-center design, lack of inter-observer reproducibility testing, and internal cutoff values that require external multicenter validation.

Subject of Research: Non-invasive splenic ultrasound and elastography assessment for predicting esophageal varices in schistosomiasis-associated non-cirrhotic portal hypertension

Article Title: Ultrasound and point shear-wave elastography assessment for predicting esophageal varices in schistosomiasis-associated non-cirrhotic portal hypertension

Article References: Pereira, C. L. D., Domingues, A. L. C., Santos, J. C., Lucas, I. C., Siqueira, E. S., Rodrigues, M. L., de Brito, C. A. A., & Lopes, E. P. (2026). Ultrasound and point shear-wave elastography assessment for predicting esophageal varices in schistosomiasis-associated non-cirrhotic portal hypertension. Abdominal Radiology. https://doi.org/10.1007/s00261-026-05762-0

Image Credits: AI Generated

DOI: 10.1007/s00261-026-05762-0

Keywords: Schistosoma mansoni, non-cirrhotic portal hypertension, esophageal varices, point shear-wave elastography, splenic stiffness measurement, splenic index, splenic vein diameter, liver stiffness measurement, hepatosplenic schistosomiasis, periportal fibrosis, Niamey classification, upper gastrointestinal bleeding, upper gastrointestinal endoscopy, abdominal ultrasonography, diagnostic accuracy, clinically significant portal hypertension

News Source: Ophelia Keating. (November 24, 2026). Spleen Imaging Accurately Predicts Esophageal Varices in Schistosomiasis Portal Hypertension. Scienmag.