Nine-Variable Triage Score Accurately Predicts Sepsis Across Multicentre
A newly developed nine-variable clinical scoring tool can accurately identify sepsis at emergency department triage without relying on laboratory tests or complex computational infrastructure, according to a multicentre retrospective cohort study encompassing
Illustrative imageA newly developed nine-variable clinical scoring tool can accurately identify sepsis at emergency department triage without relying on laboratory tests or complex computational infrastructure, according to a multicentre retrospective cohort study encompassing more than 3.7 million patient visits. The tool, named the Emergency Sepsis Risk Prediction score, was derived from nearly 2.5 million patient encounters within the University of Minnesota healthcare system and validated across two independent external medical systems in the United States. Across all three health systems, the transparent integer-based score demonstrated consistent discriminative performance, achieving an area under the receiver operating characteristic curve between 0.784 and 0.822. By drawing exclusively on clinical information available immediately upon presentation—specifically patient age, vital signs, chief complaints, and concise diagnostic coding history—the model reliably stratified patients into four distinct risk tiers before clinical workups commenced, outperforming every bedside clinical scoring system currently in widespread emergency department use.
Sepsis remains one of the primary causes of in-hospital mortality worldwide, defined clinically as life-threatening organ dysfunction brought on by a dysregulated systemic host response to infection. However, early identification remains exceptionally difficult because presenting symptoms are inherently heterogeneous and overlap with many non-infectious acute illnesses. Traditional bedside screening tools were not engineered for triage-based sepsis identification: the Sequential Organ Failure Assessment score requires laboratory parameters unavailable during initial triage, the quick Sequential Organ Failure Assessment displays poor diagnostic sensitivity, and physiological warning scores such as the National Early Warning Score 2 and Rapid Emergency Medicine Score were built to forecast general inpatient deterioration rather than infection. Meanwhile, proprietary machine learning models integrated into electronic health records frequently act as opaque algorithms that must be locally retrained for each hospital site and depend on laboratory investigations that take hours to return.
To overcome these systemic barriers, investigators structured a multivariable prediction development and validation study adhering strictly to the Transparent Reporting of a multivariable prediction model for Individual Prognosis Or Diagnosis artificial intelligence guidelines. The derivation cohort comprised 2,487,095 adult emergency department encounters recorded between January 2010 and December 2022 across eleven urban, suburban, and rural emergency departments within the M Health Fairview system at the University of Minnesota. An additional 671,189 subsequent visits from January 2023 through January 2025 at the same institutions served as the internal validation cohort.
Development of the score relied on the machine learning AutoScore framework applied to 63 candidate triage variables within the derivation training set. Continuous variables were categorised, ranked by random-forest importance, and converted into an additive point scale using logistic regression, scaling coefficients to a total ceiling of 100 points. Rather than retaining purely data-driven mathematical cut-points, the investigators aligned continuous parameters with established clinical thresholds, incurring only a negligible 0.0024 reduction in discriminative area under the curve while drastically improving intuitive bedside interpretability. The final model incorporates nine specific variables: a chief complaint of fever or chills assigns 20 points; age 70 years or older assigns 14 points, while ages 30 to 69 assign 9 points; systolic blood pressure below 90 mm Hg contributes 14 points, while 90 to 179 mm Hg contributes 3 points; diastolic blood pressure below 60 mm Hg adds 11 points, while 60 to 89 mm Hg adds 6 points; oxygen saturation below 94 percent adds 11 points, and 94 to 98 percent adds 3 points; respiratory rate of 22 breaths per minute or higher assigns 9 points, and 18 to 21 breaths per minute assigns 3 points; heart rate of 110 beats per minute or higher contributes 6 points, and 90 to 109 beats per minute contributes 3 points; two or more hospitalisations within the prior 365 days yields 6 points; and a pre-existing fluid or electrolyte disorder recorded in the Elixhauser Comorbidity Index contributes 9 points.
When evaluated in the validation cohorts, the fixed score achieved an area under the receiver operating characteristic curve of 0.815 in the internal validation cohort, 0.784 in the Beth Israel Deaconess Medical Center cohort, and 0.822 in the Stanford Health Care cohort. Head-to-head statistical comparisons using paired DeLong tests confirmed that the Emergency Sepsis Risk Prediction score significantly exceeded triage acuity alone, as measured by the Emergency Severity Index, which registered areas under the curve between 0.672 and 0.698. It also substantially surpassed the quick Sequential Organ Failure Assessment, which achieved values from 0.595 to 0.649, the National Early Warning Score 2, which ranged between 0.665 and 0.756, the systemic inflammatory response syndrome criteria, ranging from 0.575 to 0.761, as well as the Modified Early Warning Score, the Rapid Emergency Medicine Score, and the Cardiac Arrest Risk Triage score. Notably, at the University of Minnesota sites, where the proprietary commercial Epic Sepsis Model was actively deployed, the new open integer score outperformed the commercial tool by an absolute margin of 0.119 in area under the curve, despite the commercial algorithm having access to subsequent laboratory results including serum lactate and procalcitonin.
The scoring architecture divides presenting emergency patients into four actionable clinical risk tiers: low risk for scores below 21, moderate risk for scores between 21 and 30, high risk for scores from 31 to 44, and very high risk for scores of 45 and above. Across all three healthcare systems, observed sepsis rates escalated monotonically across these tiers, expanding by 35-fold to 51-fold from the lowest tier to the highest tier. In the internal validation cohort, observed sepsis incidence progressed from 0.41 percent in the low-risk tier to 1.38 percent in the moderate-risk group, 5.90 percent in the high-risk group, and 20.28 percent in the very-high-risk group. In the external cohorts, patients scoring 45 or higher experienced observed sepsis rates of 28.01 percent at Beth Israel Deaconess Medical Center and 24.49 percent at Stanford. Crucially, the very-high-risk category generated an average of only 3.6 to 6.9 clinical alerts per emergency department per day, concentrating high-probability cases into a manageable volume where approximately one in every three to five flagged encounters represented true sepsis, avoiding alert fatigue.
Comprehensive misclassification analyses revealed distinct clinical profiles among sepsis presentations that fell above versus below predefined thresholds. In the low-risk tier scoring under 21 points, the score yielded negative predictive values exceeding 99 percent across all three health systems, with sensitivity ranging from 95.2 to 96.5 percent. Sepsis cases occurring within this lowest band accounted for under five percent of all sepsis presentations, and these individuals exhibited markedly lower in-hospital mortality rates—0.7 percent at the University of Minnesota, 3.7 percent at Beth Israel Deaconess Medical Center, and 2.4 percent at Stanford—compared to 6.4, 9.8, and 7.1 percent among detected cases. When evaluating presentations missed at the moderate-to-high threshold of 31 points, false-negative cases were younger, presented with less acute triage severity ratings, maintained higher initial blood pressure, and exhibited lower heart rates than detected patients. However, within the consensus Sepsis-3 clinical criteria definition, patients missed at this cut-point systematically experienced longer delays before receiving antimicrobial therapy across all cohorts, recording median times to first antibiotic of 3.42 to 3.83 hours compared to 1.88 to 2.98 hours among patients correctly identified by the score.
Extensive sensitivity and subgroup investigations demonstrated robust discrimination across diverse patient subpopulations and practice environments. Discriminative performance remained strong across emergency departments categorised as rural, suburban, or urban, yielding areas under the curve spanning 0.794 to 0.849, and held across emergency triage acuity levels 1 through 4. Discrimination also proved resilient among difficult-to-diagnose clinical cohorts, including patients presenting afebrile at triage, patients lacking any documented chief complaint of fever or chills, older adults, and immunocompromised individuals.
While the ranking and discriminative capacity of the score proved transferable across geographic regions, the unadjusted mathematical probability mapping under-predicted absolute risk when exported outside the derivation health system. In the internal validation cohort, the calibration intercept was positive 0.176 with a slope of 0.956 and an observed-to-expected ratio of 1.17, whereas Beth Israel Deaconess Medical Center registered a calibration intercept of positive 0.875, a slope of 0.780, and an observed-to-expected ratio of 2.05, and Stanford exhibited an intercept of positive 0.507, a slope of 0.911, and an observed-to-expected ratio of 1.54. These discrepancies reflect baseline differences in patient case-mix, underlying sepsis prevalence, and local clinical coding habits between academic institutions. Importantly, the researchers demonstrated that locally recalibrating the intercept alone—an undemanding statistical adjustment requiring no structural re-estimation of the model weights—successfully restored the observed-to-expected ratio to 1.000 across all validation cohorts while leaving the relative ranking of patient risk entirely intact.
The study authors highlighted several methodological limitations inherent to retrospective electronic health record evaluations. Sepsis status was identified using a composite outcome combining international classification discharge codes with clinical Sepsis-3 criteria, both of which are vulnerable to documentation variation and unmeasured timing of infection onset. Additionally, all participating cohorts were drawn from large United States academic health systems, and the derivation population included a smaller proportion of Black and Hispanic patients than recorded in national ambulatory surveys. Crucially, the score was evaluated retrospectively using baseline triage measurements alone; no attending healthcare staff acted upon the score in real time, and the retrospective study design cannot prove that deploying the score directly shortens time to treatment or reduces patient mortality. The research team concluded that prospective clinical trials are now needed to display the risk tiers at point-of-care emergency department triage and evaluate whether clinician responses translate into improved clinical outcomes.
Subject of Research: Emergency department triage machine learning score for early sepsis identification
Article Title: Development and external validation of an interpretable machine learning score for early sepsis identification in the emergency department: a multicentre retrospective cohort study
Article References: Jin, Y., Huang, X., Wang, Y., Wacker, D. A., Puskarich, M. A., & Xie, F. (2026). Development and external validation of an interpretable machine learning score for early sepsis identification in the emergency department: a multicentre retrospective cohort study. eClinicalMedicine, 102, Article 104346. https://doi.org/10.1016/j.eclinm.2026.104346
Image Credits: AI Generated
DOI: 10.1016/j.eclinm.2026.104346
Keywords: sepsis, emergency department, triage, machine learning, clinical prediction model, external validation, ESRP score, vital signs, infection, risk stratification, electronic health records, SOFA score, qSOFA, NEWS2, clinical decision support, hospitalisation, mortality
News Source: Ophelia Keating. (November 25, 2026). Nine-Variable Triage Score Accurately Predicts Sepsis Across Multicentre Emergency Department Cohorts. Scienmag.